Product Description
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V AC coil
TeSys K
Contactors and reversing contactors up to 7.5kW 400/415V
Features
- Common options available for all ratings: 6, 9, 12 A
- Control circuits available: AC, DC, low-consumption DC, silent
- Applications: 2.2 kW, 4.5 kW, 5.5 kW in AC3 and AC4
- Connectors: screw clamp, faston connectors, spring terminals, pins for printed circuit boards
Benefits
- Compact performance
- Tesys k forms a complete range of reversing or non-reversing contactors, offering the best performance/compactness ratio and seamless integration in all your applications.
Application
- Industry, infrastructure, building, etc :
- Simple control systems
- Zones sensitive to noise, disturbed mains supplies: silent contactor
- Use compatible with programmable controller outputs: low-consumption contactor
Download
Environment | |
Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
Mechanical robustness | Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6 |
Operating altitude | 2000 m without derating in temperature |
Protective treatment | TC conforming to IEC 60068 TC conforming to DIN 50016 |
Main | |
Associated fuse rating | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 |
Auxiliary contact composition | 1 NO |
Average impedance | 3 mOhm at 50 Hz - Ith 20 A for power circuit |
Contactor application | Resistive load Motor control |
Control circuit type | AC 50/60 Hz |
Device Application | Control |
Device short name | LC1K |
lrms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 |
Motor power kW | 2.2 kW at 400 V AC 50/60 Hz AC-4 2.2 kW at 220...230 V AC 50/60 Hz AC-3 4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440 V AC 50/60 Hz AC-3 4 kW at 480 V AC 50/60 Hz AC-3 4 kW at 500...600 V AC 50/60 Hz AC-3 4 kW at 660...690 V AC 50/60 Hz AC-3 |
Operating rate | 3600 cyc/h |
Operating time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing |
Overvoltage category | III |
Poles description | 3P |
Power pole contact composition | 3 NO |
Product certifications | UL CSA |
Product name | TeSys K |
Product or component type | Contactor |
Range | TeSys |
Rated breaking capacity | 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Utilisation category | AC-4 AC-1 AC-3 |
[Ie] rated operational current | 9 A at <= 440 V AC AC-3 for power circuit 20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit 16 A (<= 70 °C) at 690 V AC AC-1 for power circuit |
[Ith] conventional free air thermal current | 20 A at <= 50 °C for power circuit 10 A at <= 50 °C for signalling circuit |
[Uc] control circuit voltage | 24 V AC 50/60 Hz |
Complementary | |
Auxiliary contacts type | Type instantaneous (1 NO) |
Control circuit voltage limits | 0.2...0.75 Uc at <= 50 °C drop-out 0.8...1.15 Uc at <= 50 °C operational |
Heat dissipation | 1.3 W |
Hold-in power consumption in VA | 4.5 VA at 20 °C |
Inrush power in VA | 30 VA at 20 °C |
Insulation resistance | > 10 MOhm for signalling circuit |
Minimum switching current | 5 mA for signalling circuit |
Minimum switching voltage | 17 V for signalling circuit |
Non Overlap Distance | 0.5 mm |
Signalling circuit frequency | <= 400 Hz |
Warranty | |
Warranty period | 18 months |
SCHNEIDER CONTACTOR (K TYPE), 2.2 / 4KW ~ 9A ~ 1NO ~ 24VAC, (LC1K0910B7)
- Brand: Schneider
- Product Code: LC1K0910B7
- Availability: In Stock